What AS 2870 covers
AS 2870 Residential slabs and footings sets requirements for classifying a site and for designing and constructing footing systems for single dwellings, townhouses and similar buildings. It is referenced by the National Construction Code for Class 1 and Class 10a buildings. A soil test, usually by a geotechnical consultant, provides the classification; the engineer then designs a slab or footing that suits it.
This article explains the logic of the classes and how they influence design. It does not reproduce the standard, and every house needs a site-specific classification and design.
The classes in plain terms
Reactive clays swell when they get wet and shrink when they dry. The movement at the ground surface over the expected range of moisture conditions is called the characteristic surface movement, written ys, and it sets the class for clay sites.
- Class A: mostly sand and rock sites with little or no ground movement from moisture changes
- Class S: slightly reactive clay, ys up to about 20 mm
- Class M: moderately reactive clay or silt, ys about 20 to 40 mm
- Class H1 and H2: highly reactive clay, ys about 40 to 60 mm and 60 to 75 mm
- Class E: extremely reactive, ys above about 75 mm
- Class P: problem sites, such as soft soils, uncontrolled fill, landslip risk, mine subsidence, collapsing soils or abnormal moisture conditions, which need engineering design rather than standard footings
How the class changes the slab
A raft slab resists ground movement through stiffness. As the expected movement increases, the edge beams and internal beams get deeper and closer together, and reinforcement increases. A house on Class A sand may sit on a modest slab with shallow edge beams, while the same house on Class H2 clay needs much deeper beams and more steel to keep differential movement within limits that the walls and finishes can tolerate.
The wall type matters too. Articulated masonry veneer tolerates more movement than full masonry, and the design accounts for that. Changing from lightweight cladding to brick late in a project can mean redesigning the slab.
What pushes a South East Queensland site to Class P
Many lots in the region are classified P for reasons other than clay reactivity. The common ones are uncontrolled fill from earlier earthworks, soft alluvial soils near creeks, cut-and-fill pads where part of the slab sits on fill and part on natural ground, steep slopes with landslip risk, and land within mapped mining areas around Ipswich.
Houses are built on Class P sites every day, with footings designed by an engineer for the actual condition, which may involve piers or screw piles to firmer ground, removal and replacement of fill, or a stiffer slab supported on the natural soil.
Drainage, trees and the life of the footing
The design assumes the site will be maintained within normal moisture conditions. Leaking pipes, ponding against the slab edge, garden beds that are heavily watered next to the house and large trees close to the building all push moisture outside that range and cause movement the footing was never designed for.
For that reason the engineer's drawings usually include drainage requirements: ground falling away from the slab, stormwater connected to a lawful point of discharge and plumbing trenches backfilled so they do not channel water under the house. CSIRO and HIA publish homeowner guides on foundation maintenance that are worth passing on at handover.
Pools, extensions and retaining walls
Pool shells, retaining wall footings and extensions rely on the same soil information as the house. A pool designed for Class M clay with a 100 kPa bearing capacity may need piers if excavation finds softer or more reactive material, which is why engineering drawings for pools often instruct the builder to stop and call the engineer if conditions differ from the report.
An extension adds a second footing system next to an existing one. If the original house sits on a different footing type or the ground has changed since it was built, the junction between old and new needs detailing so the two parts can move without cracking.
Practical steps for builders and owners
Order the soil test early, before the slab design is requested, and make sure the geotechnical consultant knows where the house sits on the lot and whether any cut or fill is planned. Tell the engineer about wall types, any heavy elements such as stone benches or a pool nearby, and the expected finished floor level relative to natural ground.
On site, check that the excavation matches the report. If fill, soft ground, water or rock appears where it was not expected, stop and ask the engineer. A short delay at excavation costs far less than repairing a cracked house.
Keep the soil report and the engineering drawings with the property records. A later owner planning a pool, an extension or a retaining wall will need the same information, and having it saves a second investigation or at least narrows what it needs to cover.
General information for Queensland projects, not advice for a specific site. Written by Coreline Engineering; engineering for a project is carried out or supervised by Mustafa Koc, RPEQ 35981.