Skip to content
Coreline Engineering

Reinforced concrete design

We design reinforced concrete slabs, beams, columns, walls, cores and basements for commercial, industrial, community and multi-residential buildings. The design is documented to AS 3600 for building approval and for the formwork, reinforcement and concrete trades on site.

Structural engineering

Typical projects

  • Suspended slabs and transfer floors in low and mid-rise buildings
  • Basements, car parks and podium structures
  • Industrial ground slabs, plinths and equipment bases
  • Concrete cores, shear walls and stair structures
  • Community, school and health buildings with long-span floors

Problems this work solves

Deflection that cracks finishes
A slab can be strong enough and still sag enough to crack tiles and partitions. Long-term deflection, creep and shrinkage often govern slab depth more than strength does.
Congested reinforcement
Beam-column joints and transfer zones fill up with bars quickly. If concrete cannot be placed and compacted around them, the drawn strength is never achieved on site.
Penetrations added late
Services openings cut through slabs and walls after design can remove the very steel that carries the load. Early coordination with hydraulic and mechanical consultants avoids redesign during construction.
Exposure in coastal and wet areas
Concrete near the coast, in car parks and in wet areas needs cover and concrete grade chosen for durability, or reinforcement corrosion starts years before the design life is reached.

What our engineering covers

Coreline's role is design, documentation, assessment and inspection. Construction, supply and installation sit with the builder and trades.

  • Comparison of slab and framing systems at concept stage, including flat plate, band beam and post-tensioned options where they suit
  • Structural analysis and member design to AS 3600 under AS/NZS 1170 loads
  • General arrangement, reinforcement and detail drawings for building approval and construction
  • Coordination of penetrations, set-downs and embedments with the architect and services consultants
  • Review of reinforcement shop drawings and contractor queries
  • Pre-pour reinforcement inspections where engaged

Design considerations

Slab system against programme
A flat plate is quicker to form and easier for services, while band beams carry longer spans with thinner slabs. The right choice depends on the grid, the floor-to-floor height and how fast the builder needs to cycle floors.
Crack control by exposure
Reinforcement for crack control is set by exposure and by whether cracks are acceptable at all. A basement wall against groundwater is detailed differently from an internal office slab.
Construction loads
Back-propping, early stripping and loads from stacked materials can exceed the in-service load on young concrete. We note construction-stage assumptions on the drawings so the builder can plan around them.

What you typically receive

The exact deliverables are set in the fee proposal for each project.

  • Structural drawings covering general arrangement, reinforcement and details
  • Design certification for building approval (Form 15) where required
  • Structural notes covering concrete grade, cover and exposure classification
  • Responses to builder and certifier requests for information
  • Inspection certificates (Form 16) for inspections we carry out

What to send us

  • Current architectural plans, sections and elevations
  • Geotechnical report, or confirmation that one is being commissioned
  • Site survey with levels and existing services
  • Proposed use of each floor and any heavy plant or storage loads
  • Services layouts showing major penetrations, if available
  • Target programme and procurement method

Standards and regulations that usually apply

Which documents govern a design depends on the project. These are the ones most often relevant here; we confirm the applicable editions for each job.

AS 3600
Design and construction of reinforced and prestressed concrete structures and members.
AS/NZS 1170 series
Structural design actions: permanent, imposed, wind, earthquake and other loads used in every structural design.
NCC (Building Code of Australia)
Performance requirements for buildings. In Queensland NCC 2022 applies until 30 April 2027 and NCC 2025 from 1 May 2027.

Questions we are asked

How thick does a suspended concrete slab need to be?

It depends on the span, the support conditions, the loads and how much deflection the finishes can tolerate, so there is no single answer. Deflection often controls the depth, which is why a slab carrying brittle tiles over a long span ends up deeper than strength alone would require.

Is post-tensioning worth it for a mid-rise building?

It is often worth pricing once spans get long or floor-to-floor height is tight, because post-tensioned slabs are thinner and carry longer spans. The trade-off is a specialist subcontractor, stricter control of penetrations and more planning for future alterations.

Can you check a builder's alternative to the drawn design?

Yes. We review alternative reinforcement, construction joints or slab systems proposed by the builder and confirm in writing whether they meet the design intent, or what changes they need.

Sources

Need reinforced concrete design?

Tell us what you are building or assessing, where it is and what drawings or reports you already have. We will come back with questions, a scope and a fee.

Registered engineer
Mustafa Koc, RPEQ 35981 (Civil)
Add company, role and timing (optional)

We use these details only to respond to your enquiry. See our privacy policy. Please do not attach or paste plans here; we will ask for them by email once we have spoken.

Call 1300 924 666Discuss your project